> Markdown version of [/jobs/ext/4729444-facilities-command-center-engineer](https://www.wearedevelopers.com/jobs/ext/4729444-facilities-command-center-engineer). Every page supports `.md` or `Accept: text/markdown`. Links point to the HTML versions so they work for humans too. Agent guide: [/agents.md](https://www.wearedevelopers.com/agents.md). --- # Facilities Command Center Engineer - **Company:** Coreweave Inc - **Location:** Kenilworth, United States - **Experience:** Experienced - **Salary:** $109,000 - $160,000 - **Contract:** Temporary contract - **Skills:** Applicant Tracking Systems, Data Centers, Data Center Infrastructure Management (CIM), Uptime - **Published:** November 15, 2026 - **Apply:** https://startup.jobs/facilities-command-center-engineer-night-position-coreweave-2-9926930 ## About the Role * 4+ years of experience operating or maintaining critical facilities: data centers, utilities and power generation, hospitals, semiconductor fabs, or industrial plants. * Hands-on background in electrical systems (UPS, switchgear, generators, ATS/STS, batteries) or mechanical systems (chillers, CRAH/CRAC, cooling towers, pumps, controls), with working knowledge of the other. * Ability to read and reason from one-line diagrams, P&IDs, and sequences of operation. * Proven experience writing, reviewing, and executing SOPs, MOPs, and EOPs in high-availability environments. * Experience making operational decisions under pressure with incomplete information, and explaining the reasoning afterward. * Ability to interpret telemetry, trend data, and alarm behavior to separate real risk from noise. * Strong written communication. Much of your work product is the written record of what happened, why, and what to change. * Ability and willingness to work 12.5-hour shifts on a fixed two-week rotating pattern, including weekends, holidays, and nights if assigned to a night crew. * Work is performed in a climate-controlled Command Center, primarily seated at a multi-monitor operator workstation. Preferred Skills: * Bachelor's degree in Electrical or Mechanical Engineering, or equivalent military technical training (for example, Navy nuclear or marine engineering programs). * Experience as a data center facility engineer, critical facilities engineer, or chief engineer in a hyperscale or colocation environment. * Stationary engineer, electrical, or HVAC trade license. * Data center operations certifications such as CNet CDCTP or Uptime Institute AOS/ATD. * Familiarity with specific BMS, EPMS, and DCIM platforms. * Experience in a centralized Command Center, Facility Operations Center, or NOC supporting multiple sites. * Experience with root cause analysis methods and incident management frameworks. Wondering if you're a good fit? We believe in investing in our people, and value candidates who can bring their own diversified experiences to our teams, even if you aren't a 100% skill or experience match. Here are a few qualities we've found compatible with our team. If some of this describes you, we'd love to talk. * You love to understand how a system really behaves, not just what the alarm says. * You're curious about why the same failure keeps showing up at different sites. * You're an expert in staying calm and making a sound call during high-severity incidents. * You're the kind of person who notices the number that's slightly wrong before anyone else does. ## Description The Global Data Center Operations team serves as the backbone of our infrastructure, ensuring the seamless performance of our global hyperscale environment. Operating in a high-stakes, 24/7 setting, this team is responsible for safeguarding the availability, stability, and reliability of mission-critical systems that power our most essential services. As a Facilities Command Center Engineer, you bring facilities engineering judgment to mission control for our global data center fleet. Where a site engineer owns one building, you see every building at once. You will conduct structured remote rounds across every site we operate using BMS, EPMS, DCIM, and every other telemetry source available to us, and when something looks wrong, you are the person who works out what it means. Our telemetry is not always timely or clean, and not every alarm has a runbook. This role exists for those moments. You will read one-line diagrams and sequences of operation, diagnose electrical, mechanical, and fire protection events from incomplete data, decide whether and where to send people, and make sure work in the field is safe and authorized before it starts. This is a remote engineering role performed from the Command Center. You will not be turning wrenches, but you need to understand the equipment as if you had, because the person turning the wrench is relying on your call., Diagnose moderate-to-high complexity issues across electrical, mechanical, and fire/life safety systems using telemetry, one-line diagrams, P&IDs, sequences of operation, and equipment documentation. * Make the call when no runbook fits: assess risk to production, decide whether to dispatch, and direct the first response within defined limits. * Review work requests, MOPs, and change records submitted by site teams and vendors for safety and operational compliance before work is authorized. * Conduct scheduled remote rounds each shift, reviewing and recording the health of electrical, mechanical, and fire/life safety systems across the fleet. * Monitor critical assets including UPS systems, standby generators and fuel systems, switchgear, PDUs, battery plant, chillers, CRAH/CRAC units, cooling towers, pumps, air handlers, and fire suppression systems. * Baseline normal operating conditions, trend performance across sites, and identify drift and early-warning signatures before they become events. * Serve as first responder for infrastructure alarms, triaging incidents and initiating response per SOPs, MOPs, and EOPs. * Escalate to on-site operations, engineering teams, and leadership based on defined escalation matrices, with a clear technical assessment attached. * Coordinate incident response across multiple teams and sites, and remotely support on-site technicians, vendors, and contractors during events and planned maintenance. * Write and correct operating procedures based on what you see across the fleet, and feed lessons learned back to site leadership. * Act as technical lead on root cause analysis, providing timelines, alarm histories, and an engineering read of what failed and why. * Coach Command Center Technicians on your crew and help them build the facilities depth to grow into this role. * Maintain detailed event logs and lead structured shift handovers to keep operations continuous across crews. Work Schedule: Our Command Center operates 24/7/365. You will be assigned to a night crew, * Shift: 12.5 hours, including a 30-minute handover overlap at each end of the shift. * Rotation: A fixed two-week repeating pattern (2-2-3) with every other weekend off. Depending on crew assignment, you will work either: + Sunday, Wednesday, Thursday in week one; Monday, Tuesday, Friday, Saturday in week two, or + Monday, Tuesday, Friday, Saturday in week one; Sunday, Wednesday, Thursday in week two. * Cycle: Three scheduled shifts in one week and four in the next, repeating. You will never work more than four shifts in a single week. * Night differential: Night crew assignments are paid a 10% shift differential. * Holidays: The Command Center is staffed on holidays. Holiday coverage is part of the rotation. * Handover: Every shift begins and ends with a structured handover. Punctuality is a safety requirement, not a preference. * On-site presence: This role is performed from the Command Center and requires on-site presence for the duration of each shift.