Data Center Controls Integration Governance Manager (SCADA/BMS/EPMS)

Precision Inc.
Covington, GA, United States
3 months ago

Role details

Contract type
Permanent contract
Employment type
Full-time (> 32 hours)
Compensation
$115,000.0 - $150,000.0
Working hours
Regular working hours
Job source

Tech stack

Computer Programming Computer Literacy Data Centers Data Presentation Software Design Documents Supervisory Control and Data Acquisition (SCADA) Modbus Network Connections OPC Unified Architecture Simple Network Management Protocols Systems Integration Virtualization Technology
+5 more
Data Ingestion Test Scripts Change Tracking Bacnet Allen-Bradley Factory Automation Equipment

Job description

  • Morning: Confirm SCADA configuration and Division 25 BMS/EPMS activities are tracking to plan; resolve constraints with other trades and the EOR.
  • Mid-day: Drive integration checkpoints-validate data ingestion from BMS and EPMS through the Integration Control System (ICS) layer into SCADA; ensure cybersecurity alignment with Owner/EOR standards.
  • Afternoon: Administer change control, review subcontractor SOVs and AIA billing, and update cost forecasts and risk logs.
  • Late day: Facilitate commissioning readiness-SCADA Level 2-5 and BMS/EPMS Level 1-5-confirm documentation completeness and plan IST participation.

What you govern

  • Primary point of contact for SCADA, BMS, and EPMS subcontractors on PEC’s behalf.
  • Execution oversight of SCADA configuration/implementation and Division 25 BMS/EPMS scopes.
  • Strict adherence to issued EOR design documents, standards, and Owner requirements.
  • Contract rulebook: scope, schedule, quality, safety, and documentation enforcement; progress and deliverables tracking.
  • Cross-discipline coordination with PEC teams, other trades, commissioning agents, the Owner, and the EOR to hit phased construction, commissioning, and turnover milestones.

Where you draw the line (what this role does not do)

You ensure others execute correctly; you do not perform system design or programming. You enforce that subcontractor efforts stay within configuration, implementation, integration, monitoring, visualization, alarming, and data presentation. You also enforce exclusions, including:

  • Control system design services
  • PLC, RTU, or OEM equipment programming
  • OEM equipment logic development
  • Relay protection configuration
  • Arc flash studies
  • Electrical construction or trade work

You verify that others provide physical infrastructure, pathways, power distribution, network connectivity, virtualization platforms, and core cybersecurity controls as assumed in subcontracts.

Change management and commercial stewardship

  • Run formal change order processes for any deviation from EOR documents.
  • Identify scope gaps, conflicts, or risks early and escalate with options.
  • Review SOVs and AIA applications for payment for accuracy and compliance.
  • Support cost forecasting, change tracking, and financial reporting for assigned scopes.

Commissioning, testing, and turnover

  • Coordinate subcontractor participation across SCADA Level 2-5 and BMS/EPMS Level 1-5 commissioning.
  • Support Integrated Systems Testing (IST) planning and execution.
  • Verify complete, high-quality turnover documentation, including SCADA configuration records, tag lists/point schedules, alarm matrices and priorities, graphics inventories, test scripts and results, and as-builts.
  • Ensure training, system walk-throughs, and knowledge transfer occur per contract.

Requirements

Do you have experience in Systems integration?, * Track record managing large industrial automation, critical facilities, or data center projects.

  • Strong subcontractor management with contractual and financial oversight experience.
  • Proven ability to control scope and enforce contractual boundaries.
  • Deep understanding of SCADA, BMS, and EPMS architectures.
  • Experience orchestrating complex multi-discipline system integrations.
  • Polished communicator with Owners, Engineers, subcontractors, and internal leadership.

Technical proficiency

  • SCADA platforms, including Ignition SCADA
  • Rockwell / Allen-Bradley control environments
  • Protocols: BACnet, Modbus, OPC-UA, SNMP
  • Familiar with data center operations, redundancy concepts, and commissioning methodologies (strong plus)

Preferred

  • Hyperscale data center delivery experience
  • Knowledge of Division 25 specifications and Integrated Systems Testing (IST)
  • Experience working within a formal Engineer of Record (EOR) model, * Construction Management
  • Electrical Schematics
  • Electrical Troubleshooting Skills
  • Electrical Systems Diagnostics & Repair
  • Electrical Troubleshooting
  • Blueprint Reading
  • Basic Computer Skills

Apply for this position

This job is hosted externally. Click below to view the full posting and apply.

Apply on indeed.com

Good distractions

Talks and stories from around this role — technically off-topic, practically not.

51 sec

Repurposing hardware and operating underwater data centers

Chris Heilmann +1 · LIVE

3:09 min

Balancing data science skillings alongside systems engineering rigor

Nico Schmidt · LIVE

4:03 min

Managing massive power consumption scaling in AI data centers

Stephan Gillich Stephan Gillich +3 · WWC 2024

7:05 min

Managing outage risks through infrastructure hardware redundancy

Kurt Eder · LIVE

3:46 min

Navigating a career in cloud transformation consulting

Piet Van Dongen · LIVE

4:56 min

The energy consumption of internet growth and data centers

Roy Derks · JS Congress

Videos

See all

Related articles

See all