Next up World Congress Europe Jul 14–16, 2027 · Berlin Find out more

Commissioning Engineer, Electrical I/II - Data Center (REMOTE)

The Anchor
Ann Arbor, MI, United States
1 day ago
Apply on www.careerbuilder.com
Prepare application

Role details

Contract type
Permanent contract
Employment type
Full-time (> 32 hours)
Experience required
1 year minimum
Compensation
$95,000 - $123,000
Working hours
Regular working hours

Tech stack

Data Centers Uptime Computer Network Operations Test Scripts

Job description

  • Do pre-functional checks and Level 2-3 readiness inspections on electrical equipment
  • Run functional performance tests (FPT, Level 4) using approved procedures, under supervision at Level I and on your own at Level II
  • Support integrated systems testing (IST, Level 5), including utility-failure, generator transfer and recovery scenarios
  • Work with electrical contractors, equipment makers (OEMs) and the controls team during startup and testing
  • Carry out electrical commissioning work assigned by Senior Engineers, Leads and the Cx PM. Record test results, deficiencies and corrective actions, and keep commissioning documentation accurate and timely (e.g., in CxAlloy)
  • Read and mark up one-line diagrams, schematics and sequences of operation
  • Follow strict safety practices around energized equipment: LOTO, NFPA 70E and arc-flash boundaries, * Safe, accurate execution of assigned testing
  • Complete, defensible commissioning documentation
  • Responds well to direction and feedback
  • Steady technical growth and readiness for more responsibility (Level I Level II Senior)

Requirements

Network Operations Center, Commissioning - Engineering, Electrical Engineering, Network Operations Center, Electricity, Commissioning - Engineering, Electrical Engineering, Willing to Travel, Commissioning, Testing, * Bachelor’s degree in Electrical Engineering, or equivalent hands-on electrical experience. Military electrical, power-production or nuclear experience counts as equivalent (e.g., Navy Nuclear EM/ET, Air Force 3E0X1/3E0X2, Army 12P/12R, Marine 1141/1142)

  • 2-7 years in electrical systems work, such as utility, power generation, heavy industrial, manufacturing, construction, inspection or commissioning
  • Working knowledge of power distribution: switchgear, transformers, UPS, generators and automatic transfer switches
  • Ability to read and interpret electrical one-lines and schematics, and a basic understanding of redundancy and failure concepts
  • Willingness to learn commissioning processes and tools; ability to travel 75% and work on active construction sites

Preferred:

  • Data center or other mission-critical experience (hospitals, utilities, semiconductor or pharmaceutical plants)
  • Exposure to startup, testing or commissioning
  • OSHA 10 or 30; NFPA 70E training; commissioning-related coursework or training
  • Electrical inspector, journeyman or master electrician background, or military electrical/power experience (Navy nuclear, Air Force 3E0, Army 12P Prime Power)

LEVEL I VS. LEVEL II

  • Level I: 2-5 yrs industry, 1-3 yrs mission-critical. Runs Level 1-4 test scripts under supervision. Learning one-lines, sequences and test discipline.
  • Level II: 4-7 yrs industry, 2-4 yrs mission-critical. Runs Level 4 FPT on own and supports Level 5 IST. Building documentation and punch-list skills; working toward Uptime ATD or similar certification.

Benefits & conditions

  • Competitive base salary, plus eligibility for our performance bonus program
  • Travel expenses and per diem covered under company policy
  • Medical, dental, vision and other benefits
  • A clear career ladder from Engineer to Senior to Lead, with both technical and leadership tracks
  • A firm built on discipline, not heroics. We own outcomes together, hold the line under pressure, and follow the process even when it’s harder.

About the company

Southeast Michigan built the power systems behind American industry. Bring that electrical know-how to the data centers powering what comes next, on projects nationwide., Anchor Mission Critical commissions the data centers that keep the modern world connected. We start working on a project early, test every system right the first time, and don’t treat commissioning as a checkbox. We’re hiring Electrical Commissioning Engineers at two levels. Level I is for engineers building their commissioning foundation. Level II is for engineers ready to run functional testing on their own. You’ll test the power systems that keep hyperscale facilities running: switchgear, UPS, generators and everything between the utility and the rack., Anchor Mission Critical is a professional services firm built to support hyperscale and high-reliability infrastructure. We provide commissioning, integrated systems testing (IST), QA/QC and operational readiness services for data centers and other no-fail environments. Our Playbook sets a standard delivery framework built on readiness, risk prevention and repeatable execution.

This position is full-time and exempt. Employment is at-will, subject to applicable state and federal law. Pay above the posted range may be considered for exceptional experience or faster development.

Anchor Mission Critical is an equal opportunity employer. Veterans and transitioning service members are encouraged to apply.

Apply for this position

This job is hosted externally. Click below to view the full posting and apply.

Apply on www.careerbuilder.com
Prepare application

Good distractions

Loading talks and stories from around this role…